DAVIS 종합 계측기 - 한국대리점 코린스계기(주)
 | |
| The instrument’s built-in display and setpoint control eliminate the need for separate power supply |
| Designed to control
the flow of non-corrosive gases, the Model 810C Mass-Trak mass flow
controller meets the same performance criteria as any industry-standard
flow controller... at half the price.
The instrument’s
built-in display and setpoint control eliminate the need for separate
power supply and readout electronics, necessary on most MFCs. A
straight, large diameter sensor tube prevents clogging and
contamination, and its stable, fast response valve provides precise
one-step control of critical gas flows. You simply set it and forget it.
|
| |
|
Features
|
- Utilizes
thermal sensing principle for mass flow measurements
- Electromagnetic
valve provides continuous control
- Complete
control system in one small package
- Replaces
obsolete rotameters
- NIST
traceable calibration ensures measurement accuracy
|
| |
|
| CAT
NO. |
 |
MODEL |
 |
DEscRIPTION |
 |
AVAIL |
 |
PRICE |
| SA677110 |
|
810M |
|
Mass Flow
Meter |
|
Yes |
|
1,069,200
|
| Standard
configuration includes; 0-5 VDC and 4-20 mA linear output signals; 24
VDC input power; ¼ " female NPT inlet/outlet fittings; Viton®
“O” rings; 15 pin D-connector and mating connector; calibrated for
any flow range from 0 to 20 SCCM up to 50 SLPM equivalent nitrogen flow;
1.5% FS accuracy; maximum temperature 122 degrees F; maximum pressure
150 psig |
| SA677111 |
|
810C |
|
Mass Flow
Controller |
|
Yes |
|
1,890,000
|
| Same
as above, but includes integral flow control valve. Standard model
requires 24 VDC regulated input power; switchable 0-5 VDC and 4-20 mA
command signal |
| SA677112 |
|
DR |
|
OPTIONAL
3 1/2 digit display reading flow
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
| SA677113 |
|
1 |
|
OPTIONAL
1/8 inch compression fitting (up to 15 SLPM)
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
| SA677114 |
|
2 |
|
OPTIONAL
¼ inch compression fitting
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
| SA677115 |
|
MP |
|
OPTIONAL
Medium Pressure (40-100 psig)
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
| SA677116 |
|
LF |
|
OPTIONAL
Low flow calibration (0 to 20 SCCM full
scale flow range) FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
| SA677117 |
|
810-T8 |
|
OPTIONAL
110VAC power supply
FOR Gas Mass Flow Controller |
|
Yes |
|
129,600
|
| |
|
|
 | |
 |
|
 |
|
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다. |
|
 |
|
 |
|
|
 | |
 |
|
 |
|
이 상품에 대한 질문이 아직 없습니다.
궁금하신 사항은 이곳에 질문하여 주십시오. |
|
 |
|
 |
|
|
|
DAVIS 종합 계측기 - 한국대리점 코린스계기(주)
|
|