710 SERIES CALIBRATOR |
|

|
|

|
|

|
- Rosemount ÆÞ½º Æ®·£½º¹ÌÅÍ¿Í È£È¯
- RTDÃâ·ÂÀ¸·ÎºÎÅÍ ¿Âµµ ÃøÁ¤
- RTDÃâ·Â ½Ã¹Ä·¹ÀÌÆ®
- 7°¡Áö ŸÀÔÀÇ RTD »ç¿ë°¡´É
- ÀúÇ×ÃøÁ¤ ±â´ÉÀ» »ç¿ëÇÏ´Â RTDsÃøÁ¤
- ÀúÇ×¼Ò½º ±â´ÉÀ» »ç¿ëÇÏ´Â RTDs½Ã¹Ä·¹ÀÌÆ®
- Ⱦ¾,¼·¾¾ ¼±Åñâ´É
|
|
Function |
Range |
Resolution |
Accuracy |
|
Measure/Simulate RTD |
- -200 to 800¡ÆC
- (Pt 100)
|
0.1¡ÆC, 0.1¡ÆF |
0.33¡ÆC, 0.6¡ÆF (Pt 100) |
|
Measure/Simulate W |
15W to 3200W |
0.1W |
0.1W to 1W | | |
|

|
|

|
- TC Ãâ·ÂÀ¸·ÎºÎÅÍ ¿Âµµ ÃøÁ¤
- TC Ãâ·Â ½Ã¹Ä·¹ÀÌÆ®
- 9°¡Áö ÇüÅÂÀÇ ¿Àü½Ö »ç¿ë°¡´É
- mV¼Ò½º±â´ÉÀ¸·Î ¼±Çü TC Æ®·£½º¹ÌÅÍ ±³Á¤
- Ⱦ¾, ¼·¾¾ ¼±Åñâ´É
- Àü½Ö mini-jack Å͹̳Î
- Ç÷çÅ© 700TC1, TC2, ¿Àü½Ö Mini-plug kits
|
|
Function |
Range |
Resolution |
Accuracy |
|
Measure/Simulate mV |
- -10 to 75 mV
|
0.01 mV |
0.025%+
|
|
Measure/Simulate TC |
- -200 to 1800¡ÆC
depending on type
- (K,-200 to 1370¡ÆC)
|
0.1¡ÆC or ¡ÆF (1¡ÆC or ¡ÆF BRS)
|
0.3¡ÆC | |
|

|
|

|
- 0-20mA,4-20mAÀÇ ·çÇÁÀü·ù(Á¤È®µµ 0.015%,ºÐÇØ´É1uA)
- PLCs,Æ®·£½º¹ÌÅÍÀÇ º¼Æ® Ãâ·Â ÃøÁ¤
- 24mA·çÇÁ Àü·ù ¼Ò½º
- 100mV¿¡¼ 10VÀÇ ¼Ò½ºÀü¾Ð
- Àü·ùÃøÁ¤°ú µ¿½Ã¿¡ 24V ·çÇÁ °ø±Þ
|
|
Function |
Range |
Resolution |
Accuracy |
|
Measure/Simulate mV |
0 to 100 mV |
0.1mV |
0.025% |
|
Measure/Simulate V |
0 to 10V |
0.001V |
0.02% |
|
Measure/Simulate mA |
0 to 24 mA
|
0.001 mA |
0.02% |
|
Loop Supply |
24 Vdc |
N/A |
+/- 10% | |
|

|
|

|
- ¾Ð·Â, Àü·ùÃøÁ¤°ú ÇÔ²² P/IÆ®·£½º¹ÌÅÍ ±³Á¤
- Á¤È®µµ: 0.05 % of full scale
- 1/8 inch NPT female ¾Ð·Â ÇÇÆÃ
- Fluke 700Pxx ¾Ð·Â¸ðµâÀ» »ç¿ëÇÏ¿© 10,000 psi/69mPa ¾Ð·ÂÃøÁ¤
- Á¤È®µµ 0.025% ·Î mAÃøÁ¤
- 24V ·çÇÁÆÄ¿ö °ø±Þ
- 11°¡ÁöÀÇ ´ÜÀ§ »ç¿ë °¡´É
- Á¦·Î, ÃÖ¼Ò, ÃÖ´ë¿Í Ȧµå ±â´É
|
|
|
Function |
Range |
Resolution |
Accuracy |
|
717 30G |
Measure/Simulate Pressure |
0-30 Psi (207 kPa) |
0.001 Psi 0.01 kPa) |
0.05% |
|
Measure/Simulate mA |
0.001 mA |
0.001 mA |
0.025% |
|
717 100G |
Measure/Simulate Pressure |
0-100 Psi (690 kPa) |
0.01 Psi 0.1 kPa) |
0.05% |
|
Measure/Simulate mA |
0 to 24 mA |
0.001 mA |
0.025% | |
|

|
|

|
- ³»ÀåµÈ ÆßÇÁ
- Á¤È®µµ 0.05%ÀÇ ¾Ð·ÂÃøÁ¤
- Fluke-700Pxx ¾Ð·Â¸ðµâ»ç¿ëÀ¸·Î 10,000 psi / 700 bar ¾Ð·ÂÃøÁ¤
- ±¤¹üÀ§ÇÑ ¾Ð·ÂÃøÁ¤ ´ÜÀ§ ¼±ÅÃ
- Àü·ù ÃøÁ¤
- 24V ·çÇÁÆÄ¿ö °ø±Þ
- ÃÖ¼Ò, ÃÖ´ë, Ȧµå ±â´É
- ÀÛÀº »çÀÌÁî¿Í °¡º¿î ¹«°Ô
- °ß°í¼º°ú ½Å·Ú¼º
|
|
|
Function |
Range |
Resolution |
Accuracy |
|
718 30G |
Measure/Simulate Pressure |
0-30 Psi (207 kPa) |
0.001 Psi 0.01 kPa) |
0.05% |
|
Measure/Simulate mA |
0.001 mA |
0.001 mA |
0.025% |
|
Source Pressure, Burlt-in Pump |
-11 pisg to full scale |
|
|
|
718 100G |
Measure/Simulate Pressure |
0-100 Psi (690 kPa) |
0.01 Psi 0.1 kPa) |
0.05% |
|
Measure/Simulate mA |
0 to 24 mA |
0.001 mA |
0.025% |
|
Source Pressure, Burlt-in Pump |
-11 pisg to full scale |
|
| | | |
|
|
 | |
 |
| ¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
 |
|
 |
|
|
 | |
 |
| ¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
 |
|
ÀÌ »óǰ¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº À̰÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
 |
|
 |
|
|
 | |
|
ÀÌ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù. | |
|
|
Á¾ÇÕ °èÃø±â ¼îÇθô °è±â.com www.koreainstrument.com ÀüÈ: 031-777-1588 k@korins.com
|
|
| |
| ȸ»ç¼Ò°³ | ¼ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æÄ§ |
|
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅØ½ÃÆ¼1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆÇ¸Å¾÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
|
|
|
|
|